Specification:
Parameters:
Four Parameters: NIBP, Pulse Rate, SpO2, TEMP.
Wave forms:
SpO2 wave form
Features:
1. Intelligent monitoring NIBP, SpO2, PR, Pulse Strength, PLETH and TEMP;
2. Bright and clear LED and LCD display;
3. Compact, light for handing and easy operation;
4. Audio and visual alarm when sensors off or alarm limit exceeded;
5. Storage and review of patient's NIBP data up to 900 groups and SpO2, TEMP trend data up to 3150 groups. The data is never lost even when power's off;
6. Three kinds of power supply, AC Power, Build-in rechargeable Li-ion battery and Common AA alkaline or rechargeable batteries;
7. Automatic shut down, shut down time adjustable from 2~15Min;
8. History data uploading to a personal computer for display, observing and printing;
Applications:
This model can be applied in the hospital's operation room, ICU, clinic section office, Out-patient department, sickroom and emergency treatment.
Standard Packing List:
NIBP extension tube 1PC
Adult NIBP cuff 1PC
Adult SpO2 Sensor(include TEMP Probe) 1PC
AC power adaptor 1PC
Communication cable 1PC
Selectable Accessory:
Pediatric NIBP cuff
Pediatric SpO2 sensor
H. S. Code: 90181930
Dimension: 160mm× 148mm× 85mm
Net Weight: 565g
Gross Weight: 980g
Package Size: 245× 185× 100mm
Technical specification
Specifications:
NIBP:
Patient: Adult and Pediatric
Measurement method: Oscillometric
Range: Adult: 30mmHg~255mmHg Pediatric: 30mmHg~160mmHg
Measurement unite: MmHg/kPa selectable
Measurement mode: Manual, Auto, STAT
Measurement Type: SYS, DIA, MAP
Measurement interval in AUTO mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60Min
Measuring period in STAT mode: 5 Min
Resolution: 1mmHg
Over-pressure protection: Adult: 300mmHg Pediatric: 220mmHg
SpO2:
Patient: Adult, child
Range: 0 -100%
Resolution: 1 %
Accuracy: ± 2 %(90~99%), ± 3 %(70~89%), unspecified (< 70%)
PR:
Range: 30bpm~250bpm
Resolution: 1bpm
Accuracy: ± 2bpm
Environment: Temperature Operation: 0° C~45° C
Transportation and storage: -20° C~60° C
Humidity Operation: 15%~95 %( non-condensing)
Transportation and storage: 10%~95% (non-condensing)
Altitude
Operation: 86kPa ~106kPa
Transportation and storage: 50kPa~106kPa
Power Requirements: AC power adaptor
Input: AC 100~240V, 50/60Hz, 0.7A
Output: DC 8.4V, 1A
Internal battery
Type: 1500mAh/7.2V Li-ion rechargeable battery
Operating Time: 5 hours of stand-by time with a full battery.
Recharge time: 8 hours
Company informayion :
Company Name
|
Sainty International Group Jiangsu Sumex Imp.&Exp.Co.LTD
|
Contact Person
|
dong fang Yin (Your message will be sent to the supplier directly)
|
Address
|
8F,Foreign Trade Building,,No.18 West Wengchang Road,YangZhou,Jiangsu,China
|
Telephone
|
86-514-85168444
|
Fax
|
86-514-85168445
|
Why choose us :
Product packing :
FAQ :