• Sperm Concentration Rapid Test Cassette for Self Use
  • Sperm Concentration Rapid Test Cassette for Self Use
  • Sperm Concentration Rapid Test Cassette for Self Use

Sperm Concentration Rapid Test Cassette for Self Use

Type: Test Strips & Test Tube
Material: Plastic
Ethylene Oxide Sterilization: Ethylene Oxide Sterilization
Quality Guarantee Period: Three Years
Group: Adult
Logo Printing: with or Without Logo Printing
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2006

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
STY-ST02
Certification
CE, FDA, ISO13485
Medical Device Regulatory Type
Type 1
Medical Devices Ad. Approval No.
6018982323
Medical Devices Reg./Record No.
6078340032
Test Width
2.5mm
Shape
Cassette
Certificate
Ce and ISO
Reaction Time
15 Minutes
Transport Package
Neutral Carton Packing/ OEM Available
Specification
Strip / cassete
Trademark
Sainty
Origin
Jiangsu, China
HS Code
90303320
Production Capacity
1000000PCS/Month

Product Description

Sperm Concentration Test is a rapid test for qualitative detection of sperm concentration in human semen, as an aid in the determination of a man's fertility status.
For in vitro diagnostic use only. Suitable for self-testing use.
 
WHEN TO COLLECT SEMEN FOR THE TEST?
Wait at least 48 hours, but no more than seven days after your last ejaculation.
 
HOW TO COLLECT SEMEN?
1. Wash your hands and genitals with soap.
2. Collect your semen sample by manual stimulation (masturbation), in the semen collection cup provided.
3. Ejaculate directly into the semen collection cup without losing any portion of the semen. Do not use a condom to collect the sample. (If you do lose any semen, discard the sample, rinse the cup with tap water only and let it air dry before using it again. Do not use soap or detergent to wash the cup. Wait at least 48 hours, but no more than seven days to recollect a new semen sample.)
4. After collecting the sample, let the cup stand upright on a flat surface.
5. Samples may be tested up to 3 hours after collection. Discard sample if not tested within 3 hours and wait at least 48 hours to obtain a fresh sample to test.
6. When you are ready to test, follow the instructions in the next section,
 
HOW TO DO THE TEST?
1. Gently shake the collection cup with semen then let the sample standing for at least twenty(20) minutes, but no more than 60 minutes for the semen to become thin ( liquefied) before testing. (The semen sample
is too thick for test immediately after ejaculation).
2. Gently stir the sample in the collection cup with the semen transfer device for 10 times.
3. Unscrew the cap of the solution bottle. Transfer 0.1 ml of the sample into the solution bottle with the semen transfer device, avoid any bubbles.
4. Screw the cap of solution bottle tightly and gently mix the sample thoroughly. It's recommended to turn the solution bottle upside down for 5-10 times.
5. Let the solution bottle standing for 2 minutes.
6. Remove the testing cassette from the sealed pouch by tearing at the notch and place the testing cassette on a flat surface.
7. Unscrew the smaller cap of the solution bottle, and add 2 full drops of the semen sample on the sample well of the cassette vertically.
8. Wait for 5-10 minutes and read the result. Do not read results before 5 minutes or after 10 minutes.
 
HOW TO READ THE RESULTS?
Positive (+)
Colored bands are visible in both the control region (C) and the test region (T). It indicates a positive result (the sperm concentration ≥15×106 /ml).
Negative (-)
A colored band is visible only in the control region (C). No color band appears in the test region (T). It indicates a negative result (the sperm
concentration <15×106/ml).
Invalid
No visible band at both region, or there is a visible band only in the test region but not in the control region. Repeat with a new test cassette.
Please make sure the adding sample volume is enough. If the test still fails, please contact the distributor for technical assistance.


Packing: Neutral packing or OEM available

Lead time: within 3-4 weeks after receipt of the dawn payment of 30% of total amount

We will always be at your best service.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now